04 Apr Corrosion Under Insulation: The 7 Inspection Methods You Must Know About

As Marc Grenier discussed in The Corrosion Under Insulation Plague: What You Need to Know, corrosion under insulation (CUI) is one of the most difficult corrosion processes to prevent. The reason for that is, by and large, no matter the precautions taken, water invariably seeps into the insulation and begins its dirty work—sometimes unseen until process leakage occurs. Data shows that about 60% of pipe leaks are caused by CUI. That’s not good.

CUI is difficult to find because the insulation covers the corrosion problem until it is too late. Removing insulation, inspecting, and then reinstating the insulation after inspection is an expensive process. Inspecting without removing insulation and weather jackets greatly reduces the cost of inspections. Non-destructive testing methods to detect CUI in such a way is therefore a major benefit to the industry.

There are a number of methods used today to inspect for CUI. No one method is ever used by itself—several methods complement each other for optimal results, but that’s not the object of this article.

The most common and straightforward way to inspect for corrosion under insulation is to cut plugs in the insulation that can be removed to allow for ultrasonic testing. The other commonly used methods are radiography, and complete insulation removal. More advanced methods include pulsed eddy current. Here are the seven most common methods of inspecting for CUI with their pros and cons.

Visual Inspection

The first and simplest method of inspection is, of course, visual inspection. It involves removing the insulation, checking the surface condition of the pipe, and replacing the insulation. It’s also the most expensive and time-consuming method. The logistics of insulation removal occasionally involves asbestos and attendant complications. Process-related problems may also occur if the insulation is removed while the piping is in service. Nowadays, visual inspections are usually performed with portable visual scanners, which allows for precise, traceable sizing of surface corrosion at the outer diameter.

There are two basic types of visual inspection:

Complete Insulation Removal

  Pros Cons
  All outer diameter surface is inspected Expensive — need to replace insulation
  Sizing Outer diameter defect only
  Traceability Asbestos (occasional)

Partial Insulation Removal

  Pros Cons
  Less expensive than complete removal Inspection limited to small areas
    Possibility of water ingress
    All insulation repairs must be properly done

Neutron Backscatter

This method as used for NDT is designed to detect wet insulation in pipes and vessels. A radioactive source emits high-energy neutrons into the insulation. If there’s moisture in the insulation, the hydrogen nuclei attenuate the energy of the emitted neutrons. The inspection instrument’s gauge detector displays a low-energy neutrons count proportional to the amount of water in the insulation. High counts per time period indicate more moisture and a higher probability of the present of CUI.

  Pros Cons
  Relatively quick and accurate method
to identify areas for potential CUI 
Screening tool
  Access elevated areas without scaffolding Cannot detect or measure corrosion
  Light, versatile to reach congested areas Generates false indications

X-Rays or Radiography

X-rays are used in a variety of ways in detecting CUI, such as real-time radiography (RTR), computed radiography (CR), and digital detector arrays (DDA; flat-panel detectors).

Real-Time Radiography

RTR provides a view of a pipe’s outer diameter profile through the insulation. The real-time device has a radiation source and an image intensifier/detector. There are two major categories of RTR devices on the market today; one using an X-ray source and one using a radioactive source. Each has its own advantages and disadvantages, but the X-ray systems deliver far better resolution than the isotope-type equipment. If there is a change in the outer diameter profile, it normally means a corrosion buildup. However, it’s not possible to measure thickness and difficult to correlate the loss in wall thickness and the corrosion profile. The method is limited to small structures and requires access to both sides.

  Pros Cons
  Real-time digital imaging Radioactivity—Health and safety hazard
  Fast analysis Lower contrast sensitivity and limited
resolution compared to film-based radiography
  Traceability Uneven illumination, lack of sharpness,
noise in image
  Digital archiving Performance decreases as wall thickness/pipe diameter  increases
  Less need for repeat exposures Limited to small structures
    Requires access to both sides of component

Computed Radiography

CR uses equipment very similar to conventional radiography, except that in place of a film to create images, it uses an imaging plate made of photostimulable phosphor. A special cassette placed under the body part or object to be examined houses the imaging plate and the X-ray exposure is made. Hence, instead of taking an exposed film into a darkroom for developing in chemical tanks or an automatic film processor, the imaging plate runs through a special laser scanner, or CR reader, that reads and digitizes the image. The digital image can then be viewed and enhanced using software with functions very similar to other conventional digital image-processing software, such as contrast, brightness, filtration, and zoom.

  Pros Cons
  Real-time digital imaging Expensive imaging plates can be damaged and generate image artifacts
  Fast analysis Imaging plates sensitive to fogging — must be erased daily
  Traceability Overexposure tends to degrade contrast
  Digital archiving Limited to areas accessible to imaging plate
  Less need for repeat exposures Performance decreases as wall thickness/pipe diameter increases
  Wide range of thicknesses by adjusting image brightness and contrast Health and safety hazard—Health and safety hazard
    Limited to small structures
    Requires access to both sides of component

Digital Detector Array

DDAs or flat-panel detectors (FPD) are a class of solid-state X-ray digital radiography devices similar in principle to image sensors used in digital photography and video. X-rays pass through the object being imaged and strike one of two types of detectors: indirect detectors or direct FPDs. They are more sensitive and faster than film. Their sensitivity allows a lower dose of radiation for a given picture quality. They are lighter, far more durable, smaller in volume, more accurate, and have much less image distortion than image intensifiers/detectors and can also be produced in larger sizes.

  Pros Cons
  Real-time digital imaging Requires more power than RTR to
generate usable images
  Fast analysis Performance decreases as wall thickness/pipe diameter increases
  Traceability   Health and safety hazard—Health and safety hazard
  Digital archiving  Limited to small structures
  Less need for repeat exposures  Requires access to both sides of component
  Less image distortion than RTR  
   Compact  

Ultrasonic Thickness Measurement

This method (referred to as UT) is the non-destructive measurement of the local thickness of a solid element based on the ultrasound wave’s time of flight. This type of measurement is usually performed with an ultrasonic thickness gauge. This is an effective method, but limited to small areas. Just as with partial removal of insulation, it’s expensive to cut plugs out of the insulation and impractical to cut enough holes to get reliable results. The inspection plugs can compromise the integrity of the insulation and add to the CUI problem, if they are not properly recovered.

  Pros Cons
  Wall thickness measurement capabilities Inspection limited to small areas
  Traceability Possibility of water ingress
  Does not require access to both sides of test surface All insulation repairs must be properly done
  Engineered to cope with coatings, linings, etc. Requires calibration for each material
  Good accuracy (0.1 mm and less) using
standard timing techniques
Requires good contact with test surface

 

Pulsed Eddy Current

PEC is an electromagnetic method to determine the wall thickness of electrical conductors. The PEC probe is placed on an insulated pipe or vessel. A magnetic field is created by an electrical current in the transmitting coil of the probe. This field penetrates through the weather sheeting and magnetizes the pipe wall. Next, the electrical current in the transmission coil is switched off, causing a sudden drop in the magnetic field. As a result of electromagnetic induction, eddy currents are generated in the pipe wall. The eddy currents diffuse inwards and decrease in strength. The decrease in eddy currents is monitored by the PEC probe and is used to determine the wall thickness. The thicker the wall, the longer it takes for the eddy currents to decay to zero. Applied operating principles of PEC varies from system to system. Generally, to obtain a quantitative wall thickness reading, PEC systems use algorithms that relate the diffusive behavior in time to the material properties and the wall thickness.

PEC averages wall thickness over a relatively large foot print. As a result, PEC is suitable for general wall loss, but isolated pitting defects cannot be detected, making it a screening tool only.

  Pros Cons
  Real time Screening tool
  Traceability Only applicable to carbon steel and low-alloy steel
  Does not require contact with test surface Edge effect near interfering components
  Engineered to cope with coatings, linings,
insulation, weather jackets, etc.
 
  Good accuracy (typically 10% of
remaining wall thickness)
 
  Wall thickness measurement capabilities  

Conclusion

CUI is a plague that NDT contributes to mitigate, but the variety of inspection methods all have merits that doesn’t necessarily make one better than the rest. Indeed, they often complement each other, succeeding where another fails. Specific combination of inspection methods depends greatly on specific inspection conditions.

Tell us what you think in the comments what your preferred combination of methods of inspecting for CUI is and why. It is safe to assume that no one method is ever going to eradicate CUI unless the industry comes up with materials that do not corrode.